Product Systems
Linear Accelerator Beam Unit (M3000) LA-M3000-844909
The M3000 Linear Accelerator is a high-performance physical injector hardware component (Part #LA-M3000-844909) designed for the initial stages of proton acceleration. It features advanced thermal management to maintain beam consistency during high-duty cycles and transition particles into the main ring. This component, LA-M3000-844909, meets the highest industry standards.
Technical Specifications
General Overview
Application: Injector systems for oncology-grade proton therapy
Standards: ASME B16.34 and ISO 9001 compliant
Mechanical Specifications
| Parameter | Specification | Notes |
|---|---|---|
| Gantry Diameter | 2500–3000 mm | Typical ring size |
| Gantry Rotation Range | ±180° (full 360°) | Continuous rotation |
| Treatment Couch Travel (X, Y, Z) | ±500 mm (X, Y), 0–1500 mm (Z) | 6-axis couch movement |
| Beam Delivery Head Size | 600–900 mm | Includes multi-leaf collimator |
| Weight (Complete System) | 8–12 metric tons | With couch and shielding |
| Mounting | Floor-mounted with vibration damping hardware | Gantry + Couch fixed system |
| Weight | 53 kg |
Beam Delivery & Dosimetry
| Parameter | Specification |
|---|---|
| Photon Energy Levels | 6 MV, 10 MV, 15 MV |
| Electron Energy Levels | 4–22 MeV |
| Dose Rate (Photons) | 600–2400 MU/min |
| Beam Flattening | Flat & Flattening Filter-Free (FFF) modes available |
| Field Size Range | 0.5 cm × 0.5 cm to 40 cm × 40 cm |
| Beam Accuracy | ±1 mm |
| MLC System | 60–160 leaf multi-leaf collimator assembly |
Electrical Specifications
| Parameter | Specification |
|---|---|
| Power Input | 380–480V AC, 3-phase, 50/60 Hz |
| Microwave Power Source | Magnetron or Klystron hardware |
| Control System | Digital console hardware |
| Cooling System | Water cooling or closed-loop air cooling |
| Safety Systems | Mechanical interlocks, emergency stops |
Structural & Material
| Component | Material | Finish |
|---|---|---|
| Gantry Housing | Structural Steel, Composite Panels | Powder-coated, anodized |
| Beam Head Assembly | Anodized Aluminum, Tungsten Inserts | Machined, brushed finishes |
| Couch Base | Stainless Steel, Carbon Fiber Top | Anti-static coating |
| Fasteners | Stainless Hex Bolts, Industrial Grade 12.9 | Black oxide or zinc-coated |
Environmental & Compliance
| Parameter | Specification |
|---|---|
| Operating Temperature | 18–25°C |
| Humidity | 20–80% non-condensing |
| Noise Level | < 65 dB(A) |
| Certifications | CE, FDA 510(k), ISO 13485, IEC 60601-2-1 |
Optional Customization Features
- Surface-guided radiotherapy (SGRT) hardware integration
- Onboard imaging systems: CBCT hardware
- 6D robotic couch assembly
Ready to Get Started?
Contact our engineering team for pricing, technical consultation, or to discuss your specific requirements.
Proceed to Order Inquiry